How to change a DDC Sizer closed side setting (1 reply)

C
Chromst
4 years ago
Chromst 4 years ago

Hi all,

Is it possible to change the closed side setting of a DDC sizer whilst it is operating? Are the roller and breaker bar positions fixed?

Mike
4 years ago
Mike 4 years ago

It is never a good idea to try and adjust any equipment while it is operating.  This can cause major failures and also safety issues.  You should always have the equipment shut down cleaned out and locked and tagged out before making any adjustments!!!!!!!

That said, it is possible to adjust the closed side setting when it is shutdown and locked and tagged out.  This is normally done to adjust for wear.