copper electrolyte conductivity (1 reply)

G
graeme23miller
4 years ago
graeme23miller 4 years ago

I am trying to source data on the conductivity of copper electrowinning electrolytes: Cu 30 - 50 g/L, H2SO4 150 - 180 g/L & 50 Celsius.

T
Todd H
4 years ago
Todd H 4 years ago

Why?  The baseline EW parameters apply to almost all copper solutions unless there is significant iron or other impurities in it.

https://pubs.acs.org/doi/pdf/10.1021/je8001255

https://www.nrcresearchpress.com/doi/pdf/10.1139/v83-047

Regards

Todd

Todd Harvey - Global Resource Engineering http://www.global-resource-eng.com